Installation
Instructions
PTS-0-1.5PSI-01, PTS-0-3PSI-01, PTS-0-5PSI-01
Submersible Pressure Transducers
|
WARNING – Maretron submersible
pressure transducers are not
approved for use with gasoline. If you wish to use the FPM100 to monitor
pressures or levels of gasoline, you must obtain a pressure transducer that
is approved for use with gasoline. |
Maretron’s submersible pressure
transducers are used for indicating tank levels and can be installed directly
in the tank. Please follow these instructions to mount and connect a submersible
pressure transducer to an NMEA 2000® network via a Maretron FPM100 Fluid
Pressure Monitor. Maretron recommends one of two methods for mounting a
submersible pressure transducer in a tank; 1) without
a restraining tube (shown on left side of Figure 1) and, 2) with a restraining
tube (shown on right side of figure 1).
1.
The submersible pressure
transducers are designed for a tank with a 5-Hole SAE J1810 fitting at the top.
Install the mounting plate with cord grip onto the transducer cable, with the
rounded hex section of the cord grip facing away from the transducer.
2.
Lower the pressure transducer into
the tank such that the transducer lies at the lowest point of the tank, and tighten the cord grip to secure the cable. On a
tank with a flat bottom, the transducer may slide from side to side with the
motion of the vessel, but will not rotate due to the
stiffness of the cable. It is also possible to mount the pressure transducer
inside a restraining tube or focus tube (sold separately, Maretron part number
TFT-5H). Please refer to Figure 1 for examples.
3.
Connect the two wires of the
pressure transducer to a free pressure monitoring channel as shown in Figure 2
below. The diagram shows a connection to FPM100 channel #0, but connections to
other channels are similar. Connect the white wire from the pressure transducer
to the positive (+) terminal of the channel and connect the brown wire from the
pressure transducer to the negative (-) terminal of the channel. The example in
Figure 1 shows the pressure transducer connected to switch channel 0 with the white
wire connected to “P0+”, and the brown wire connected to “P0-”. Submersible pressure
transducers have a small plastic vent tube in the connecting cable.
Care must be
taken not to kink or block this tube or pressure readings will be inaccurate.
Figure
2 – Submersible Pressure Transducer Connection Diagram
4.
Use a Maretron DSM Series Display (firmware
1.4.7 or higher) or a PC running Maretron’s N2KAnalyzer software (version 1.4.19
or higher), to configure the connected channel(s) on the FPM100.
|
PTS-0-1.5PSI-01 |
PST-0-3PSI-01 |
PST-0-5PSI-01 |
Value at 4mA: |
0 PSI (0 bar) |
0 PSI (0 bar) |
0 PSI (0 bar) |
Value at 20mA: |
1.5 PSI (0.103 bar) |
3.0 PSI (0.207 bar) |
5.0 PSI (0.345 bar) |
5.
Supply power to the NMEA 2000
network and verify that the pressure channel indicates a valid pressure reading.
Mechanical Drawing
Pressure
Transducer Specifications
Part
Number |
Operating
Range |
Depth
Range |
Cable
Length |
|
Water
(1,000 kg/m3) |
Diesel
(820 kg/m3) |
|||
PTS-0-1.5PSI-01 |
0 to 1.5
PSI (0.103 bar) |
41.5”
(1.05 m) |
50.7”
(1.29 m) |
16.4
ft (5 m) |
PTS-0-3PSI-01 |
0 to 3 PSI
(0.207 bar) |
83.1”
(2.11 m) |
101.3”
(2.57 m) |
16.4
ft (5 m) |
PTS-0-5PSI-01 |
0 to 5 PSI
(0.345 bar) |
138.4”
(3.51 m) |
168.9”
(4.29 m) |
23.0
ft (7 m) |
Specification |
Value |
Sensor Type |
Gauge (Vent Tube) |
Output |
4 – 20 mA current loop,
loop powered |
Excitation Voltage |
9 VDC to 32 VDC |
Compatible Fluids / Gases |
Diesel, Diesel Exhaust
Fluid (DEF), Hydraulic Fluid, Kerosene, Motor Oil, Fresh Water, Sea Water,
Waste Water |
Operating Temperature |
14°F to 158°F (-10°C to 70°C) |
Ambient Temperature |
14°F to 158°F (-10°C to 70°C) |
Accuracy |
±0.3% Full Scale typ. at
25°C |
Total Error Band (TEB) |
±1.0% Full Scale typ.
(-10°C to 70°C) |
Non-Linearity,
Hysteresis (NLH) |
±0.2% Full Scale typ.
Best Straight Line (BSL) at 25°C |
Temperature Compensation
Zero Point and Span |
0.04% Full Scale/°F (0.02%
Full Scale/°C) |
Long Term Stability |
0.2% Full Scale typ. 1
year at 25°C |
Rise Time |
1 ms
typ. (10%-90% nominal pressure) |
Switch-On Delay |
100 ms |
Over Pressure |
15 PSI (1.03 bar) |
Burst Pressure |
30 PSI (2.07 bar) |
Vibration |
6 g (25 to 2000 Hz) |
Shock |
50 g / 8 ms |
Construction |
AISI316L stainless steel
housing, pressure connection; Ceramic, Al2O3 (96%)
Sensor; FKM (FPM, Viton), EPDM (TPE) seals; PUR cable |
Minimum Cable Bend Radius |
1.57” (40 mm) |
EMC Compatibility |
EN/IEC 61000-6-3 / GL
2012, IV, Part 7 (Emission and Immunity) |
Weight |
12.6 oz (357 g) |
For installation support, please contact:
Maretron
120 Intracoastal
Pointe Dr.
Jupiter, FL 33477
Toll Free: +1 (866)
550-9100
Phone: +1 (602)
861-1707
E-mail: [email protected]